How to Clean the Boiler, Honeycomb? 10 Tricks

How is honeycomb cleaning done at home? It is an indispensable job to obtain efficient heat in the heating installation. Radiators experience heat losses over time and the desired level of heat is not obtained. Combi boiler cleaning and professional honeycomb cleaning are different jobs and should not be confused.

Honeycomb cleaning; It is a work that covers all pipes and honeycombs belonging to the heating system made by companies specialized in this field. Honeycomb cleaning is done using a number of special honeycomb cleaning chemicals and preservatives.

Combi boiler cleaning is done by professional craftsmen in the form of cleaning the parts inside the boiler, independent of honeycomb cleaning. At the same time, boiler maintenance should also be carried out by authorized services.

How to Clean the Honeycomb?

The first thing to do before starting honeycomb cleaning is to turn off the boiler. Then the water accumulated in the honeycomb must be drained.

Drain valvesin bathrooms can be used for this purpose. In the absence of drain valves, the water in the radiators can be drained out through the purge valve in the radiators.

After the water in the system is completely removed, the connections with the pipe should be disconnected by opening the records of the boiler combs.

How to Clean the Boiler, Honeycomb? 10 Tricks 4 – Clean the Boiler Kampa

Radiators should be removed from the wall and moved to the place to be washed. With the help of pressurized water, water can be sent into the honeycombs to wash them.

Pressurized cleaning water is sent until the dirty water is cleaned. Pressurized clean water should be applied to all honeycombs. Then, the water supply valve under the boiler is opened and water is passed to the boiler.

All honeycombs can be deaerated separately and the boiler can now be used. Apart from this, a similar process can be done by a specialized master using a honeycomb cleaning device, chemical substance and protective chemical.

How to Clean the Boiler, Honeycomb? 10 Tricks 6 – Clean the Boiler Kampa
Cleaning process with honeycomb cleaning machine.

In the boiler honeycomb cleaning to be done by an expert master, the following procedures should be followed respectively;

  • Make sure that the boiler is switched off. Since the materials inside the boiler may be affected by the dirty water in the installation, the boiler return valvemust be closed.
  • Then the towel warmer in the bathroom is removed and the machine is connected from the towel warmer inlet of the device.
  • The other end of the hose connected to the outlet valve is placed in the nearest sink or toilet bowl to allow the dirty water to drain away.
  • Water is given to the boiler cleaning machine and the boiler cleaning machine is started.
  • While the dirty water in the system is discharged, clean water is pumped into the system.
  • The outlet and inlet valves of all radiators are closed. Since the radiator cleaning will be turned off one by one, the outlet and inlet valves of the radiator to be cleaned are left open.
  • While the honeycomb cleaning chemical is sent to the heating system, the use of preservatives at the end of this process should not be neglected. All these procedures to be done with the help of an expert master will be appropriate.
  • After the honeycomb cleaning, the honeycombs should be bled.

How to Clean a Combi Boiler?

How to Clean the Boiler, Honeycomb? 10 Tricks 8 – Clean the Boiler Kampa
Kombi temizleme, kombi temizliği…

Combi boiler cleaning is done with the same logic as honeycomb cleaning. However, the issue to be considered is that the machine used is low pressure.

  • After the radiator is cleaned, the machine is connected to the place where the inlet and outlet valves of the boiler are located.
  • Clean water is supplied to the machine. The machine drains the dirty water from the boiler.
  • If a device with a heater is used, the water in the machine tank is heated. Half a liter of boiler cleaning chemical is added to the machine tank.
  • The machine circulates hot water and medicine for about half an hour.
  • The medicated water is then rinsed from the boiler.
  • Finally, the dirt traps are cleaned with a brush.
  • Water should be pumped into the installation and the boiler should be started to operate.

Why is Honeycomb and Combi Boiler Cleaning Important?

If we talk about a few items about why boiler and honeycomb cleaning is important;

  • Thanks to the cleaning and maintenance, high heat efficiency is achieved at low energy.
  • High heat is obtained from all the honeycombs in the rooms.
  • In the boiler natural gas consumption is reduced and savings are achieved in the bills.
  • Combi boiler components, especially the circulation pump, work less, extending the service life of the boiler.
  • Rust is prevented with chemical preservative to be used during cleaning.
  • Another important benefit of honeycomb heater cleaning is that the sediment accumulated in the lower parts of the pipes is opened with the help of chemicals and the blockages are removed.
  • The service life of the installation line, honeycombs and boiler is extended.

How to Practical Boiler Honeycomb Cleaning?

Honeycomb cleaning can be done in a practical way with a specialized honeycomb cleaning master who has a machine that will provide the necessary convenience for all operations.

How is natural gas honeycomb cleaning done? How to do heating pad cleaning, honeycomb washing? We have explained clear answers to all questions such as how to clean the heating honeycomb for you on our page.

How Much Does Honeycomb Cleaning Cost?

The price you will pay for an average cleaning may vary depending on the number of honeycombs and the previous time of the cleaning process, but it hovers around 500-1000TL.

Click here for our prices for honeycomb cleaning, combi boiler honeycomb cleaning, honeycomb maintenance, honeycomb cleaning at affordable prices.

For more honeycomb cleaning machine articles. Click here for information about barrel pumps.

Leave a Reply