{"id":49711,"date":"2023-07-06T13:47:05","date_gmt":"2023-07-06T10:47:05","guid":{"rendered":"https:\/\/blog.kampa.com.tr\/?p=49711"},"modified":"2025-07-29T14:08:00","modified_gmt":"2025-07-29T11:08:00","slug":"booster-failure-causes-and-solution","status":"publish","type":"post","link":"https:\/\/blog.kampa.com.tr\/en\/booster-failure-causes-and-solution\/","title":{"rendered":"Booster Failure, Causes and Solution 6 Titles"},"content":{"rendered":"\n<p class=\"has-normal-font-size wp-block-paragraph\">Why do booster failures occur? The booster is designed to be used with the expansion tank or hydromat of the pump to pressurize the water. <\/p>\n\n\n\n<p class=\"has-normal-font-size wp-block-paragraph\">Malfunctions occur when the necessary requirements of the hydrophores are not met. Hydrophore failures used for garden irrigation and daily water use are especially annoying in the summer.<\/p>\n\n\n\n<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><nav><ul><li class=\"\"><a href=\"#hidrofor-resetleme-nasil-yapariz\">How to Reset the Booster Booster<\/a><\/li><li class=\"\"><a href=\"#su-hidrofor-arizalari-nelerdir-ve-cozum-yollari\">What are Water Booster Failures and Solutions<\/a><ul><li class=\"\"><a href=\"#hidrofor-arizalari-pompa-calismiyor-devreye-girmiyor\">Booster Malfunctions Pump Not Working! Not Activated!<\/a><\/li><li class=\"\"><a href=\"#hidrafordaki-basinc-aniden-dusuyor-ve-pompa-sik-sik-devreye-giriyor\">The Pressure in the Hydraphore Suddenly Drops and the Pump Starts Frequently!<\/a><\/li><li class=\"\"><a href=\"#hidrofor-pompa-arizalari-neden-hava-yapar\">Why Booster Pump Failures Make Air<\/a><\/li><li class=\"\"><a href=\"#hidrofor-kesik-kesik-calisiyor\">Booster Works Intermittently<\/a><\/li><li class=\"\"><a href=\"#hidrofor-arizalari-surekli-calisiyor\">Booster Booster Malfunctions Continuously Running<\/a><\/li><li class=\"\"><a href=\"#hidrofor-basinc-salteri-arizasi-sebebi-onleme-yolu\">Booster Pressure Switch Failure Cause Prevention Way<\/a><\/li><li class=\"\"><a href=\"#hidrofor-normal-calistigi-halde-su-basmiyor-elektrik-motorunda-isinma-var\">The booster does not pump water even though it works normally, there is heating in the electric motor!<\/a><\/li><li class=\"\"><a href=\"#otomatik-olarak-durduktan-sonra-basinc-dusmesine-ragmen-calismiyor\">It does not work even though the pressure drops after stopping automatically!<\/a><\/li><li class=\"\"><a href=\"#motoru-vinlama-yapiyor-ve-pompa-donmuyor\">The motor is whining and the pump won&#8217;t turn!<\/a><\/li><\/ul><\/li><li class=\"\"><a href=\"#elektrik-kaynakli-hidrofor-arizalari\">Electric Booster Failures<\/a><ul><li class=\"\"><a href=\"#hidrofor-sigorta-attiriyor\">Booster Blown Fuse<\/a><\/li><\/ul><\/li><li class=\"\"><a href=\"#how-do-i-connect-a-power-cable-to-a-water-pump\">How Do I Connect a Power Cable to a Water pump?<\/a><ul><li class=\"\"><a href=\"#hidrofor-faz-hatasi-cozumu\">Booster Phase Error Solution<\/a><\/li><\/ul><\/li><li class=\"\"><a href=\"#hidrofor-arizalari-su-kaciriyor\">Booster Failures Leaking Water<\/a><\/li><li class=\"\"><a href=\"#hidromat-arizalari\">Hydromat Failures<\/a><ul><li class=\"\"><a href=\"#hidromat-basinc-ayari-nasil-yapilir\">How to Adjust Hydromat Pressure<\/a><\/li><\/ul><\/li><li class=\"\"><a href=\"#hidrofor-susuz-calisirsa-ne-olur\">What happens if the booster runs without water<\/a><\/li><li class=\"\"><a href=\"#hidrofor-arizalarini-onlemek-icin-temizlige-dikkat-edin\">Pay Attention to Cleanliness to Prevent Booster Failures!<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<p class=\"has-normal-font-size wp-block-paragraph\">Those who have a booster problem in the apartment should enter into a solution together because water is everything. Information about brake booster failure, why the booster does not work.<\/p>\n\n\n\n<p class=\"has-normal-font-size wp-block-paragraph\">You need a service that will make the plumbing that provides the necessary service for its repair without any problems. In systems where the need for water is continuous, the air in the expansion tank should not be missing.<br>Sometimes we fix simple problems without contacting authorized services. <strong>Why doesn&#8217;t the booster pump work? The booster does not work!<\/strong> Before contacting the authorized technical service, let&#8217;s see what we can do together.<\/p>\n\n\n<div class=\"wp-block-image aligncenter size-full\">\n<figure ><img decoding=\"async\" src=\"https:\/\/blog.kampa.com.tr\/en\/wp-content\/uploads\/sites\/3\/2023\/07\/booster-failure-causes-and-solution-1.jpg\" alt=\"Booster Failure Causes\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-resetleme-nasil-yapariz\">How to Reset the Booster Booster<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We do booster reset in different ways depending on the brand of the booster. The reset key or reset combination of each brand is different. Therefore, you can find these keys by examining the user manual of your booster. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To reset the Etna branded booster, it is necessary to press the up and down buttons at the same time. When you press and hold these two buttons for about 3 seconds, the reset will take place. After resetting, you must remove your hand from the keys at the same time.<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bleeding the booster<\/strong> is a process that requires expertise. If you do not have an expertise in this subject, it would be better to seek professional help. If you have expertise, it will be enough to follow these steps <strong>to bleed the booster<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>First, the booster must be disconnected from the mains.<\/li>\n\n\n\n<li> After the electrical connection is safely disconnected, the screw on the front of the motor must be loosened. <\/li>\n\n\n\n<li>The screw must not be unscrewed completely. <\/li>\n\n\n\n<li>The electrical connection must then be reactivated. <\/li>\n\n\n\n<li>After these steps, wait until the air in the motor is released. <\/li>\n\n\n\n<li>The process is completed when water starts to come out of the loosened screw after the air outlet is completed.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Please note that a professional point of view is required in solving the problems related to the booster. In this way, the problem is solved in a short time and permanently.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"su-hidrofor-arizalari-nelerdir-ve-cozum-yollari\"><strong>What are<\/strong> Water <strong>Booster Failures and Solutions<\/strong><\/h2>\n\n\n\n<p class=\"has-normal-font-size wp-block-paragraph\">Booster pump failures are usually caused by <strong>lack of water<\/strong>, <strong>irregular electric current<\/strong>, <strong>failure of the pressure switch<\/strong> and <strong>expansion tank problems<\/strong>. These failures are usually intervened without contacting a service.<\/p>\n\n\n\n<p class=\"has-normal-font-size wp-block-paragraph\">Solve the following problems, but if the solutions are not sufficient, contact a technical service.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What is a power brake <strong>booster failure<\/strong> refers to a problem that prevents or affects the operation of the booster. This type of failure is caused by <strong>a problem with<\/strong> the booster&#8217;s <strong>electrical connection<\/strong>or <strong>a malfunction in the booster&#8217;s electronic board<\/strong>.<\/p>\n\n\n<div class=\"wp-block-image aligncenter size-large\">\n<figure ><img decoding=\"async\" src=\"https:\/\/blog.kampa.com.tr\/wp-content\/uploads\/2020\/01\/hidroforlar-neden-arizalanir.png\" alt=\"Hidrofor ar\u0131zalar\u0131 neden olur\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-arizalari-pompa-calismiyor-devreye-girmiyor\"><strong>Booster Malfunctions Pump Not Working! Not Activated!<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Check whether the power is cut off.<\/li>\n\n\n\n<li>Check that the fuse is intact.<\/li>\n\n\n\n<li>Check whether there is water in the tank. (If there is no water in the tank, the float switch has cut the energy.) Wait until the tank is full of water.<\/li>\n\n\n\n<li>Check if any fault light is on on the <a href=\"https:\/\/blog.kampa.com.tr\/en\/pump-control-panel\/\" target=\"_blank\" rel=\"noreferrer noopener\">control panel<\/a>. If it is on, press the reset button.<\/li>\n\n\n\n<li>The electric motor is burnt. Contact an authorized technical service.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Read on for solutions to problems such as the booster does not start, the booster does not start automatically, why the booster pressure drops.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrafordaki-basinc-aniden-dusuyor-ve-pompa-sik-sik-devreye-giriyor\"><strong>The Pressure in the Hydraphore Suddenly Drops and the Pump Starts Frequently!<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If the booster pressure does not increase, you can do the following.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Close the outlet valve. If the pressure drops even though the valve is closed, the check valve is leaking or there is a leak in the installation line. Replace the check valve. <em>(Click here to buy a check valve<\/em>)<\/li>\n\n\n\n<li>The membrane has burst. Please contact the authorized technical service.<em>(Click here to buy membrane<\/em>)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-pompa-arizalari-neden-hava-yapar\">Why Booster Pump Failures Make Air<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Boosters <strong>suck in air when there is not enough water in the suction chamber.<\/strong> This causes the pump to make air during operation. Also, <strong>if the air in the expansion tank is missing or the membrane is burst, the booster makes noise.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-kesik-kesik-calisiyor\">Booster Works Intermittently<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There are several reasons why your booster may run intermittently. Some of these are as follows:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>The check valve in the suction line is leaking<\/strong>.<\/li>\n\n\n\n<li><strong>If your booster is a spherical booster, the air in the membrane in the sphere has disappeared or the balloon has burst<\/strong>.<\/li>\n\n\n\n<li><strong>Pump internal assembly elements are damaged<\/strong>.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If your booster is running continuously or if it is activated at frequent intervals, it is an indication that the pressure is low or that the damper has burst.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the booster is running continuously, <strong>you can remove the valve cover on the tank and press on the valve using an object such as a pen.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-arizalari-surekli-calisiyor\">Booster Booster Malfunctions Continuously Running<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If the booster is running <strong>continuously<\/strong>, you can remove the valve cover on the tank and press the valve using an object such as a pencil to see if there is any <strong>burst<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What happens if the booster is constantly running, the booster is constantly running, it does not pump water. Why the booster motor burns out, if the water pump is running but does not pump water. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pump burns out as a result of long-term behavior in this way. So why the booster works continuously, let&#8217;s look at the reasons why the booster is constantly activated.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If <strong>the booster is occasionally running on its own even though there is no water use<\/strong>, there may be several reasons for this situation:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>There is a leakage greater than 70 liters\/hour flow rate at any point of the installation<\/strong>.<\/li>\n\n\n\n<li><strong>The manual start button (RESET) is stuck<\/strong>.<\/li>\n\n\n\n<li><strong>Electronic board failure<\/strong>.<\/li>\n\n\n\n<li><strong>Faulty electrical connection<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-basinc-salteri-arizasi-sebebi-onleme-yolu\">Booster Pressure Switch Failure Cause Prevention Way<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Booster pressure switch malfunction, the cause of the booster not operating or operating at low pressure. It controls the working pressure of the booster. If it is faulty, the booster will not operate or will operate at low pressure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In order to prevent malfunction, <strong>periodic maintenance of<\/strong> the booster is required. During booster maintenance, it is important to check the pressure switch and replace it when necessary. The booster pressure switch remains stuck,<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Also, the <strong>water level<\/strong> in the water tank <strong>must be sufficient<\/strong> during booster operation. If the water level in the water tank is not sufficient, the booster will not operate or will operate at low pressure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For more information on <strong>booster pressure switch repair<\/strong>, please consult a specialist.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-normal-calistigi-halde-su-basmiyor-elektrik-motorunda-isinma-var\"><strong>The booster does not pump water even though it works normally, there is heating in the electric motor!<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We can try the following steps for problems such as the booster does not flood, why the booster does not flood, the booster works but does not flood.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The water in the tank is empty. Do not start the booster until the tank is full of water.<\/li>\n\n\n\n<li>The hydrophore is drawing air from the suction line. Check the suction line.<\/li>\n\n\n\n<li>The valve on the suction line is closed. Open it.<\/li>\n\n\n\n<li>The filter in the suction line is clogged. Clean it.<\/li>\n\n\n\n<li>The pump has air in it. Notify the authorized technical service.<\/li>\n\n\n\n<li>The motor is reversing. Notify the authorized technical service. Contact without thinking for all booster malfunctions that you need to notify the authorized service.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"otomatik-olarak-durduktan-sonra-basinc-dusmesine-ragmen-calismiyor\"><strong>It does not work even though the pressure drops after stopping automatically!<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The pressure switch is defective. Replace it. If you think you cannot replace it yourself, contact the technical service.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"motoru-vinlama-yapiyor-ve-pompa-donmuyor\"><strong>The motor is whining and the pump won&#8217;t turn!<\/strong><\/h2>\n\n\n<div class=\"wp-block-image alignright size-full\">\n<figure ><img decoding=\"async\" src=\"https:\/\/blog.kampa.com.tr\/wp-content\/uploads\/2023\/09\/yuksek-voltaj-koruyucu.jpg\" alt=\"voltage protector\"\/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>If the motor is <strong>three-phase<\/strong>, one of the phases is not coming. Check the fuse and switch.<\/li>\n\n\n\n<li>If the motor is <strong>single-phase<\/strong>, the capacitor is broken<\/li>\n\n\n\n<li>The engine is stuck.<\/li>\n<\/ul>\n\n\n\n<p class=\"has-normal-font-size wp-block-paragraph\">In these 3 cases, please contact the authorized service for booster malfunctions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"elektrik-kaynakli-hidrofor-arizalari\">Electric Booster Failures<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you are experiencing <strong>booster high current failure<\/strong>, you can get a current protector apparatus for your socket. You can follow the steps below for the booster low current error solution:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>First, check the electrical connection of your booster and make sure that the power is not cut off.<\/li>\n\n\n\n<li>If the electrical connection is correct, you should contact a specialist <strong>to check the low current setting<\/strong>.<\/li>\n\n\n\n<li>The low current setting varies depending on the purpose of your booster and your needs. Therefore, it is important to make the correct setting <strong>by consulting your booster&#8217;s user manual or consulting a specialist<\/strong>.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-sigorta-attiriyor\">Booster Blown Fuse<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A booster fuse blowout refers to <strong>a problem that prevents or affects the operation of the booster<\/strong>. This type of malfunction <strong>is caused by a problem with<\/strong> the booster&#8217;s <strong>electrical connection<\/strong> or there is a fault with the booster&#8217;s electronic board.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-do-i-connect-a-power-cable-to-a-water-pump\">How Do I Connect a Power Cable to a Water pump?<\/h2>\n\n\n\n<figure class=\"wp-block-video\"><video autoplay controls loop muted src=\"https:\/\/blog.kampa.com.tr\/en\/wp-content\/uploads\/sites\/3\/2023\/07\/water-pressure-system-connection.mp4\"><\/video><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-faz-hatasi-cozumu\">Booster Phase Error Solution<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A booster phase failure is an electrical fault in a booster system. You can follow the steps below for the booster phase error solution:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>First, check the electrical connection of your booster and make sure that the power is not cut off.<\/li>\n\n\n\n<li>If the electrical connection is correct, you may need <strong>to contact<\/strong> an <strong>electrician<\/strong> to check for a phase fault. You should always have your power line checked for a missing phase.<\/li>\n\n\n\n<li>In the event of a booster phase failure, <strong>it is important to contact a specialist<\/strong> to ensure the operation of your booster <strong>.<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-arizalari-su-kaciriyor\">Booster Failures Leaking Water<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A booster water leak causes the booster to lose water pressure and water is wasted. You can follow the steps below to prevent booster water leakage:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Check for water leakage in the body or connection points of your booster.<\/li>\n\n\n\n<li>If your booster is leaking water, the <strong>seals or valves<\/strong> in your booster <strong>need to be replaced<\/strong>.<\/li>\n\n\n\n<li>If the water leakage problem in your booster continues, it is important to contact a specialist.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidromat-arizalari\">Hydromat Failures<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A hydromat is <strong>a device attached to the discharge nozzle of a booster<\/strong>. What does a hydromat do? It automates the booster. The malfunctions and solutions of the hydromat are different.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about booster automatics malfunction, hydromat repair, I recommend that you consult a specialist according to the brand and model of the hydromat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Since<\/strong> hydromats <strong>are resistant to dry running<\/strong>, they <strong>are connected to the network<\/strong> without the need for a tank and have <strong>a permanent check valve <\/strong>under their bodies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hydromats, <strong>usually do not dampen water and are odorless. <\/strong>They also require no maintenance and operate silently. Hydromats allow the pump to <strong>be automatically started or stopped<\/strong> according to the water demand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hydromat malfunctions such as hydromat not activating, hydromat running continuously may be the following:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>There is a leakage greater than 70 liters\/hour flow rate at any point of the installation<\/strong>.<\/li>\n\n\n\n<li><strong>The manual start button (RESET) is stuck<\/strong>.<\/li>\n\n\n\n<li><strong>Electronic board failure<\/strong>.<\/li>\n\n\n\n<li><strong>Faulty electrical connection<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidromat-basinc-ayari-nasil-yapilir\">How to Adjust Hydromat Pressure<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">You can follow the steps below to adjust the hydromat pressure:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>First, <strong>cut off the water pressure and allow some time to wait.<\/strong><\/li>\n\n\n\n<li><strong>Wait until you reach the pressure level<\/strong> you want to set <strong>.<\/strong><\/li>\n\n\n\n<li>Close the tap and using <strong>an insulated screwdriver<\/strong> you can loosen <strong>the halt screw<\/strong> by tightening it.<\/li>\n\n\n\n<li>After completion, check the water pressure.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-susuz-calisirsa-ne-olur\">What happens if the booster runs without water<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When the booster operates without water, the booster gives a no water fault. The booster&#8217;s automatics make the impeller rotate faster. This <strong>can lead to overheating of the bearing shaft and other components.<\/strong> It can also <strong>cause the impeller parts<\/strong> in contact with the shaft <strong>to melt, causing the impeller to stick to the shaft and prevent the shaft from moving.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In <strong>cases where your booster does not flood<\/strong>, you can follow the steps below to prevent your booster from malfunctioning:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Check the electrical connection of your booster and <strong>make sure that the power is not cut off<\/strong>.<\/li>\n\n\n\n<li>If the electrical connection is correct, check that your booster is not flooding. Check that the water in the tank may be out and <strong>you can solve the problem by filling the tank with water.<\/strong><\/li>\n\n\n\n<li>If your booster is still not working, <strong>the booster may be sucking air from the inlet.<\/strong> The float may be faulty or the <strong>valve in the suction line may be closed<\/strong> or <strong>a clogged filter<\/strong> may be causing the problem.<\/li>\n\n\n\n<li>In some cases, <strong>an air fault may occur in the pump.<\/strong> If the pump is already producing air, the booster may not pump water.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If your booster is still not working or if problems persist, it is important to contact a specialist. Experts will be able to identify the fault in your booster and carry out the necessary repairs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I hope this information helps! Do you have any other questions? Please share your booster malfunctions and booster problems with us in the comments section.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hidrofor-arizalarini-onlemek-icin-temizlige-dikkat-edin\"><strong>Pay Attention to Cleanliness to Prevent Booster Failures!<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Clean the <strong>booster<\/strong>at regular intervals to prevent <strong>booster malfunctions<\/strong>. Especially make sure that the electric motor is clean. The <strong>impeller and front body of<\/strong> the pump <strong>must be clean<\/strong>.<\/li>\n\n\n\n<li><strong>Always disconnect from the mains<\/strong> when cleaning.<\/li>\n\n\n\n<li>Never hold water on it while cleaning. It is enough <strong>to wipe with a damp cloth<\/strong>.<\/li>\n\n\n\n<li>After cleaning, <strong>do not use cloth, paper, etc.<\/strong> on the electric motor, otherwise the cooling fan will not be able to suck in the required air and the electric motor will burn out.<\/li>\n\n\n\n<li>Another cause of booster malfunctions is <strong>clogging of the suction line, causing it to run without water.<\/strong> As a result of running without water, the pump stages are destroyed and the electric motor burns.<\/li>\n\n\n\n<li><em>Failure to observe the cleaning and the above rules will not be covered by the warranty.<\/em><\/li>\n\n\n\n<li>If you have installed a filter in the suction line, check its cleanliness every 15 days. Clean it if necessary.<\/li>\n\n\n\n<li>One of the most important ways to prevent booster malfunctions is control. <strong>After 6 months of use, check the check valve and the air in the tank regularly every 6 months.<\/strong> Click here for our article on the importance of the check valve.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image aligncenter size-large\">\n<figure ><img decoding=\"async\" src=\"https:\/\/blog.kampa.com.tr\/wp-content\/uploads\/2020\/01\/hidroforlar-neden-arizalanir-1.png\" alt=\"Booster Failures and Remedies\"\/><\/figure>\n<\/div>\n\n\n<p class=\"has-normal-font-size wp-block-paragraph\">In this article, I tried to explain to you the situations that may cause <strong>booster malfunctions<\/strong> and how they can be eliminated. I hope it was useful. You can share your experiences and suggestions by commenting and share our article on your social media accounts. Click for more detailed information about <a href=\"https:\/\/blog.kampa.com.tr\/en\/category\/booster\/\" target=\"_blank\" rel=\"noreferrer noopener\">booster pumps.<\/a> Click here for more information <a href=\"https:\/\/www.kampastore.com\/hidroforlar\" target=\"_blank\" rel=\"noreferrer noopener\">booster pumps price.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Why do booster failures occur? The booster is designed to be used with the expansion tank or hydromat of the pump to pressurize the water. Malfunctions occur when the necessary requirements of the hydrophores are not met. Hydrophore failures used for garden irrigation and daily water use are especially annoying in the summer. How to &hellip;<\/p>\n","protected":false},"author":1,"featured_media":51814,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[58],"tags":[],"class_list":["post-49711","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-booster"],"_links":{"self":[{"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/posts\/49711","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/comments?post=49711"}],"version-history":[{"count":0,"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/posts\/49711\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/media\/51814"}],"wp:attachment":[{"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/media?parent=49711"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/categories?post=49711"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.kampa.com.tr\/en\/wp-json\/wp\/v2\/tags?post=49711"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}